Home

Slots

Slots

BigFred tracks who may drive which locomotive address through the leaser (slotlease) in every dcc-bus daemon. Behaviour on the physical command station depends on the station kind:

LocoNet Z21
Slot table on the central Yes (~117 entries, IN_USE / COMMON) No — Z21 is push/pull over LAN
Physical slot acquire/release LocoNet driver (AcquireSlot / ReleaseSlot) Not applicable
Global slot budget (max_loconet_slots) Yes (default 80) Not used (unlimited in leaser)
Per-user driven cap Yes (default 8) Yes
Remote idle timeout Yes Yes
Slot diagnostics page Budget + occupied addresses Lease table only (no slot budget bar)

Plain loco.subscribe (view only) never creates a drive lease — on any station kind.


LocoNet

Two layers:

Layer Role
Leaser Holders, per-user cap, global budget, diagnostics
LocoNet driver Occupies / releases the slot on the central (NULL MOVE → IN_USE)

The driver reserves the slot on the central when a user with drive permission sends a drive command. The leaser only enforces policy and mirrors state via SlotObserver.

When a slot is taken (LocoNet)

Action Leaser Driver
loco.select (WS throttle) Holder + optional AcquireSlot IN_USE after select
First loco.setSpeed Reserve Acquire on SetSpeed / SendFn F0–F8
train.select Holder per powered member Acquire per member

Rejected if CanDrive fails, max_loconet_slots is full (bigfred_slot_budget_exceeded), or max_vehicles_per_user is exceeded (vehicle_cap_exceeded).

When a slot is released (LocoNet)

Situation Timing
WS switcher A→B Holder removed; slot stays IN_USE ~60 s (grace), then e-stop + ReleaseSlot. Re-select A in grace reuses the slot.
loco.deselect, session close, shutdown E-stop + release immediately
Per-user cap eviction Immediate
Boot-stop on idle roster locos Brief acquire for stop only; released if slot was not already IN_USE

WS-selected locos are not idle-released.

Z21 / WiThrottle rows in the table below apply when the command station is LocoNet (remote drives that station's bus).


Z21

The Z21 central has no LocoNet-style slot table. BigFred still uses the same leaser for bookkeeping: who drives which address, caps, idle timeout, and diagnostics.

There is no AcquireSlot / ReleaseSlot on Z21. A “lease” in the admin table means BigFred considers this user/session to be driving this address — not an IN_USE row on a slot table.

When a lease is created (Z21)

Action Leaser Z21 driver
First speed or function from Z21 app / WiThrottle Select + Touch (source=z21 or withrottle) Forwards DCC command to the central
GET_LOCO_INFO (pick loco in app) No lease — subscribe/view only
WS throttle on a Z21 layout Same as LocoNet leaser paths (loco.select / Reserve) Z21 SetSpeed / functions only

prepareHandsetLease runs on the first drive packet per address per handset session. Switching to another loco in the Z21 app does not auto-deselect the previous one (D15): each address driven recently stays leased until idle timeout or disconnect.

When a lease ends (Z21)

Situation Effect on central Leaser
Idle timeout (idle_timeout_secs, default 60 s) E-stop via Z21 LAN Lease removed
Handset disconnect ReleaseSession → e-stop affected addrs
Per-user cap eviction E-stop evicted addr Lease removed
WS loco.deselect / session close E-stop Lease removed (no slot grace — nothing to keep IN_USE on the central)

There is no max_loconet_slots check on Z21 — the limit is only how many addresses a user may drive at once (max_vehicles_per_user).

Z21 vs LocoNet remotes on the same layout

If the layout's command station is LocoNet, Z21/WiThrottle clients are not used on that bus. If it is Z21, LocoNet slot rules do not apply; only leaser caps and idle timeout matter.


Shared limits (configuration)

Admin → Command stations:

Setting LocoNet Z21
max_loconet_slots Max IN_USE slots through BigFred (default 80) Hidden / N/A
idle_timeout_secs Remote idle release (default 60 s; 0 = off) Same
max_vehicles_per_user (layout) Max driven vehicles per user (default 8) Same

Diagnosing in the UI

  1. Admin → Command stations
  2. Slot diagnostics (gauge icon) on the row
    /admin/dcc-bus/slots?cs=<id>
Panel LocoNet Z21
Slot budget used / max_loconet_slots “Active leases (no LocoNet budget)”
Per user Driven count vs cap Same
Occupied addresses Holders (user · z21 · ws · …) Same; z21 / withrottle = physical remote

Status: Live / Stale / Disconnected.